Electrical design software: questions and answers
Electrical design software questions and answers in one place: what Avenler is for, which drawings it makes, which countries' standards it covers, and what it cannot do yet. The answers come from the program's help and public pages.
Create a drawing Already have an account? Sign in
How do I use this page?
The questions are grouped by topic, and each one has its own anchor, so you can link to it directly. The answers come from the program's help and public pages; for the details, follow the links under each answer or see the full tutorial.
About Avenler
What is Avenler?
Avenler is browser-based electrical design software for building installations: you draw the floor plan, place the symbols, connect them into circuits with wiring, and the program calculates the single-line diagram from the distribution board. The drawing also produces a cable list, a circuit schedule and a bill of materials.
Who is Avenler for: electricians, electrical designers or clients?
Avenler is meant mainly for electricians and electrical designers who prepare building electrical plans. A client can view the quotation or the drawing package on a read-only link that opens without signing in, and as an invited reader can also view the project itself.
Does Avenler replace the electrical designer's professional responsibility?
No. The electrical sizing, the checks and the room minimums are for information and reflect practice; they do not replace the designer's professional responsibility or the check against the standards in force. The program is a design aid, not a permit document: the designer must verify the conformity of the plan according to the authority and the standard in force.
What is the difference between an electrical floor plan and a single-line diagram?
The floor plan shows where each device is and where the cable runs, while the single-line diagram shows what protects the circuits in the distribution board. In Avenler both come from the same project: the program calculates the single-line diagram from the board data and the circuit list.
Access
Do I need to register to use Avenler?
The calculators work in the browser without registration, but projects, drawings and quotations belong to your account. You create the account with an email address and a password and activate it with the link in the confirmation email; if the site offers it, you can also register with a Google account.
Do I need to install Avenler, and which browsers does it work in?
No installation is needed: Avenler runs in the browser. Use a current, up-to-date browser (Chrome, Edge or Firefox); the PDF is made from the browser's print function.
Can I use Avenler on a tablet or phone?
On a tablet, yes: the editor works with touch and a pen (one finger or the pen draws, two fingers pan and zoom). On a phone, Site mode is the right tool: over the drawing you can mark the status of devices and record defects and photos.
What can the program do?
What drawings can I make with Avenler?
Avenler produces electrical floor plans for each floor, cable and conduit routes, circuits and a single-line diagram calculated from the distribution board and the circuit list. The floor plan has walls, openings and rooms with the symbols of switches, socket-outlets, luminaires and other devices; each circuit has a designation, protection and cable. The cable list, circuit schedule and bill of materials can also be downloaded as XLSX or CSV.
Does Avenler make a single-line diagram?
Yes: you do not draw the single-line diagram, because the program calculates it from the distribution board data and the circuit list, so it always shows the current state. It can be printed on A4 or A3 with a title block; it cannot be edited by hand, so you change the board data instead.
Can I design a distribution board with Avenler?
Yes: the board designer shows the enclosure as rows of module slots and works from the same circuit list you entered on the floor plan. The program suggests a layout from the circuits, checks the board (for example a missing RCD or a device that does not fit in the enclosure), and the Sizing panel shows the load current and the voltage drop for each circuit.
Does Avenler calculate short-circuit current and selectivity?
Yes, as an informative calculation. From the short-circuit data entered in the Supply window, the program works out the highest prospective short-circuit current at the busbar and checks the breaking capacity of the circuit breakers, and the Selectivity panel gives a verdict for each upstream–downstream pair. The result can also be printed on the short-circuit report sheet of the drawing package; the feature does not apply in an NEC (USA) project.
Does Avenler produce a bill of quantities and material lists from the drawing?
Yes: the quantity take-off counts the devices and measures the cable routes per catalog item from the project's saved drawing. The length is calculated in three dimensions with a connection reserve and an allowance; the Lists section gives the cable list, the circuit schedule and the bill of materials, also as XLSX or CSV.
Can I make a quotation straight from the drawing?
Yes: the To quotation button on the take-off puts the lines calculated from the drawing into a new or an existing quotation, and the Update from drawing button recalculates the quantities. Recalculation does not touch a line you have edited by hand; the items come from the catalog and can be extended with manual lines.
Can I load an existing floor plan and export to DXF?
Yes. You can load an image (PNG, JPEG), a PDF or a DXF as an underlay, set the scale by marking two points a known distance apart or by entering a number, and draw over it. A DXF can also be turned into an editable drawing with the CAD import button in the top bar (save a DWG as DXF first), and the finished floor can be exported to DXF. For BIM models, the levels of an IFC2x3 or IFC4 architectural model can be used, and the electrical devices and routes can be exported to IFC4.
Is there a 3D view of the electrical plan?
Yes: the 3D button in the editor header shows the drawing in space, you can rotate and zoom it with the mouse or by touch, and the view can be saved as a PNG image. You can select a device or a route by clicking it and edit it in the right-hand panel; the layers and the circuit colouring also apply in 3D.
Can several people work on the same electrical plan?
Yes: the project owner can invite other registered users by email address as a reader, a commenter or an editor. Members of a shared project can see who is editing the same level; other people's saved changes appear within seconds, and the program merges parallel changes made to different elements automatically.
Can I use Avenler without an internet connection?
Only partly: with the Download for offline use button in Site mode, the project (drawing, devices, defects) can be downloaded to the device and then opened without a network. Offline, only the site view of the downloaded project is available; changes go into a pending queue and are synchronised when the network returns.
Does the program check the electrical plan automatically?
Yes: the Checks panel collects the warnings of the drawing rules, the board rules and the take-off into one list, and clicking a finding jumps the canvas to the element concerned. The rules are adjustable and for information only: they are aids, not declarations of conformity.
Does Avenler check bathroom zones?
Yes, for information only: the program calculates zones around the bath and the shower tray and flags a socket-outlet or a switch standing in a zone, as well as a device with a protection rating below IPX4. Zone dimensions can depend on the edition of the standard, so check the default values against the text of the standard; the rules can be switched off and the dimensions adjusted.
Can I design low-current systems such as data, TV or alarm networks?
Yes: a low-current circuit has a system (data, TV/SAT, alarm, door entry, KNX, fire alarm, public address, camera), and the program gives the system a colour and a default cable type. It prepares the layout, the routes and the list as suggestions: cable separation and equipment sizing must be checked against the standard in force and the manufacturer's requirements.
Can I design a solar PV system, an EV charger and a heat pump?
Yes, as part of the electrical plan: the Energy group of the device bar contains the solar panel, the solar inverter, the battery storage, the EV charger and the heat pump. Automatic assignment gives the large loads their own circuits. The program does not replace the inverter manufacturer's design software: it does not calculate MPPT allocation, shading or yield.
How do I print an electrical plan or save it as a PDF?
The drawing prints on A4 or A3 with a title block, and the PDF is made with the browser's Print / Save as PDF command. The drawing set combines several sheets into one print with continuous page numbering: floor plans, wall elevations, a legend, circuits and schedules.
Calculations
How do I calculate voltage drop on a cable?
Voltage drop follows from the resistance and reactance of the cable: on a single-phase supply count the out-and-back path (two conductors), on a three-phase supply use the √3 factor. The calculator works with a copper conductor at operating temperature, shows whether the result is within the 3 % (lighting) or 5 % (other circuits) limit, and gives the smallest suitable wire size (cross-section). Enter the one-way length; do not double it.
How do I choose a wire size and a circuit breaker?
Start from the operating current: choose the smallest standard circuit breaker, then the smallest copper cross-section whose corrected current-carrying capacity reaches the breaker's rated current. The capacity depends on the installation method (B2 or C), the ambient temperature and the number of circuits running together; if you enter the length, the voltage drop limit is also taken into account. It calculates for copper conductors with PVC insulation up to 63 A, and the result is for information.
How do I check that a circuit breaker will reliably trip on a fault?
Tripping is assured when the fault loop impedance (Zs) does not exceed Zs,max = 0.90 · 230 / (k · In), where the trip-curve multiplier k is 5 for B, 10 for C and 20 for D. Zs = Ze + L · ρ · (1/A + 1/A_PE); measure the supply Ze at the point of supply, because the default value (0.35 Ω) is only an estimate. The calculator also gives the maximum cable length; it applies to a 230 V line-to-protective-conductor loop with copper conductors, and the check itself must be done by measurement on site.
How many amps does a load of a given power draw?
On a single-phase supply (230 V) the current is I = P / (230 · cos φ), on a three-phase supply (400 V) I = P / (√3 · 400 · cos φ), where P is the real power in watts. For a resistive load such as a heater cos φ can be taken as 1, for motors use the nameplate value; the result also shows the apparent power (VA).
How do I calculate voltage, current, resistance and power with Ohm's law?
From any two quantities you can calculate the other two: V = I · R, I = V / R, R = V / I, and the power is P = V · I = I² · R = V² / R. This gives the exact value for DC or resistive AC loads; for a motor or a compressor the power factor must also be taken into account, for which the power and current converter is the right tool.
What size capacitor do I need for power factor correction?
The required capacitor power is Q = P · (tan φ₁ − tan φ₂) in kvar, where P is the real power in kW, φ₁ the present and φ₂ the desired power factor angle. On a single-phase (230 V) or a three-phase (400 V) supply the calculator also gives the apparent power and the current before and after correction; the exact sizing and connection must follow the manufacturer's data and the designer.
How many luminaires do I need to light a room?
The required luminous flux is Φ = E · A / (UF · MF), and the number of light sources is that divided by the flux of one source, rounded up. E is the target illuminance (lux), A the floor area, UF the utilization factor (0.5 by default) and MF the maintenance factor (0.8 by default); the calculator works to an average illuminance and does not consider luminaire placement or glare.
How do I calculate voltage drop in the DC cable of a solar PV system, and the string voltage?
The DC cable voltage drop is ΔU = 2 · L · I / (γ · A) (copper, operating temperature, L the one-way length), and the calculator also gives the smallest suitable cross-section for a 1, 2 or 3 % limit. It checks the string voltage in the cold as well, Uoc(T) = Uoc · (1 + β/100 · (T − 25)), and shows whether it fits the inverter's permitted input voltage; it does not check the current-carrying capacity of the cable or the protection.
What should the insulation resistance and the earth resistance be?
The calculator compares the measured value with the limit: on a normal circuit (up to 500 V) the insulation resistance must be at least 1 MΩ at a 500 V DC test voltage. On SELV and PELV circuits it must be at least 0.5 MΩ at 250 V DC. In a TT system with an RCD the earth resistance must not exceed 50 V / IΔn, which is 1666.7 Ω for a 30 mA RCD; the measurement and the test record must be made by a qualified person.
How do I calculate the service load of an American dwelling under the NEC?
Under NEC Article 220 there are two methods: the standard method (3 VA per square foot of general lighting, kitchen and laundry circuits, demand factors, appliances) and the optional method of 220.82. The result is the total load in VA, the current at 240 V and the recommended service (100, 125, 150 or 200 A) with the conductor; the calculation is simplified, and the service is decided by the authority having jurisdiction (AHJ) and the NEC edition in force.
Is the existing main breaker big enough to add an EV charger or heat pump?
The expansion load calculator compares two methods, the calculated load (NEC 220.83) and the method based on measured maximum demand (NEC 220.87), and shows whether the existing service is sufficient. If it is not, it suggests a service and conductor; it is meant for a single-phase, three-wire 120/240 V dwelling, above 200 A it only indicates that an engineered design is needed, and acceptance is decided by the authority having jurisdiction (AHJ).
Do the conductors fit in EMT or PVC conduit under the NEC?
The calculator compares the total cross-section of all conductors with the inside area of the conduit and checks it against the permitted fill. The limit is 53% for one conductor, 31% for two and 40% for three or more. It calculates for THHN/THWN conductors and EMT and rigid PVC (Schedule 40) conduit from ½ to 2 in trade size, and if you do not choose a conduit size it suggests the smallest suitable one; for ten 12 AWG THHN conductors, for example, ¾ in EMT is needed.
How do I get started?
How do I get started with my first project?
Register, confirm your email address with the link in the confirmation email, then create a project and a floor on the Projects page. You do not have to fill in everything in advance: if something is missing, for example a catalog item, the program warns you, and the warning leads to the place where you can fix it.
How is an electrical plan for an apartment made step by step?
The electrical plan is made in one project: project and floor, floor plan, devices and cable routes, circuits, distribution board, checks, take-off, quotation, and finally printing and handover. The order is not fixed, but the take-off and the schedules calculate from the saved drawing; for the rooms the program offers the usual device layout in one step, which you can change.
What does the room template place in a room?
Apply template places the devices required by the rule in one step: socket-outlets along the walls, a switch next to the first door on the latch side, and a luminaire in the middle of the room. The built-in templates are Room, Living room, Kitchen, Bathroom (with a protected socket-outlet) and Hall, and their values can be edited, and a modified template can be saved as a template of your own; the templates are practical suggestions that the designer must review.
Is there a sample project or template I can start from?
Yes: the New project from template button gives you a ready Apartment, Family house or US Starter House project with walls, rooms, devices, cable routes and a circuit list, which you can change as you like. If you only want to look around, the Tour on the Help page walks you through a ready sample apartment, and the Practice through an empty practice floor.
Are there teaching diagrams of electrical circuits, for example for a motor or a contactor?
Yes: the Practical circuits chapter of the help gives schematic teaching diagrams, for example for wiring an LED, the power and control circuit of a motor, a lamp controlled from two places, contactor self-holding and star–delta starting. The diagrams are schematic: they are not installation plans and give no authorization to work on live equipment.
Standards and countries
In how many languages and countries can Avenler be used?
The interface is available in 44 languages. The Standards page covers the standard references of 23 countries (designation, issuer and a link to the issuer's official page, without the text of the standard), and the symbol set can be chosen per country. Not every country's symbol set has its own drawing.
Which standards does Avenler calculate and check against?
The program refers to the standards of the country of the project's symbol set, and its calculations are based on the IEC 60364 family of standards. If a country has its own rules that the program does not follow, it states this next to the reference. The references are for information, not declarations of conformity: the text of the standard must be obtained from the issuer.
Does Avenler support the US NEC and feet and inches?
Partly, in beta: the project's electrical standard system can be set to NEC (USA) (NEC 2020, 2023 or 2026), and the unit can be imperial (feet, inches). The program knows the common residential rules (GFCI, AFCI, 20 A circuits, receptacle spacing, load center, dwelling load calculation), not the whole code; the authority having jurisdiction (AHJ) and the NEC in force decide.
Can I use Avenler to design to the Brazilian NBR 5410?
For information only, yes: NBR 5410 (Brasil) can be chosen among the electrical standard systems, and the Checks panel looks at the number of socket-outlets (TUG), the ceiling lighting point and the board's DR, TUE and DPS rules. The NBR checks have not undergone professional review, and the program does not claim conformity with the standard: the responsible designer, the local utility and the NBR 5410 in force decide.
What electrical drawing symbols does Avenler use?
Built-in symbols arranged in eight groups: switches, socket-outlets, lighting, distribution, low-current, sensors, fixed connections and energy elements. The symbols are simplified signs that follow the symbols of MSZ EN 60617 (IEC 60617), adapted to Hungarian practice; they do not replace the text of the official standard, and you can add your own symbol from an SVG file.
Data and security
Who can access a project I have shared?
The registered users whom the owner invites by email address, with three roles: a reader can only view, a commenter can comment, and an editor can change everything except the project details, archiving, sharing and deletion. When inviting, an expiry date can be set (at most 730 days), and a switch can prevent readers from exporting.
Can I download or delete my data?
Yes: on the Profile page the Download my data (ZIP) button gives you your account and company details, projects, floor plans (JSON) and background images, quotations, your own catalog and your settings; you can also delete your account there. A fresh backup is made before deletion, and the data drop out of the backups within 90 days at the latest.
Does Avenler use cookies or tracking, and does it use my data for advertising?
The program uses only the cookie that is strictly necessary for signing in, and visit measurement is anonymous: it stores no IP address or browser identifier. According to the privacy notice, the operator does not use personal data for advertising, profiling or automated decision-making, and does not sell it.
What is it for, and what is it not?
What can't the program do yet?
A wall, an opening or a room cannot be copied into a block (copying the floor transfers the whole floor). There is no automatic history between revisions: only explicitly issued revisions are stored, and there is no branching or merging. Not every country's symbol set has its own drawing.
Can I draw any circuit schematic in Avenler, for example a control wiring diagram?
No: Avenler is made for building electrical plans, not as a general drawing program. You cannot draw an arbitrary circuit schematic in it, such as a control circuit diagram, and it does not produce the wiring diagram of individual accessories, such as a two-way (in the US: three-way) switch.
When is Avenler enough, and when do I need another tool?
Avenler is enough for preparing a building electrical plan: floor plan, circuits, distribution board, take-off, quotation and printing. Another tool is needed for MPPT allocation, shading and yield calculation, which require the inverter manufacturer's design software, for the network operator's HMKE permit forms (Hungarian small-scale generation), for the equipment manufacturer's temperature-rise verification, and for arbitrary circuit schematics.
How reliable are Avenler's calculations and checks?
They are for information and reflect practice: the electrical sizing, the checks and the room minimums do not replace the designer's professional responsibility or the check against the standards in force. NEC (USA) mode is in beta and the NBR checks have not undergone professional review; always compare the result with the text of the standard in force.
Related pages
- Circuit diagram maker – what the program draws and how
- Electrical standards by country – the designation, issuer and official link of each standard
In detail in the tutorial
- Keyboard shortcuts and FAQ – the detailed question-and-answer chapter of the tutorial
- Getting started – the first steps in using the program